Explore the GD290 Series AC Drive (VFD) is a low-voltage multifunction general-purpose VFD with a power range from 0.75kW to 1000kW (380V–480V). It delivers robust performance in driving motors and can be widely applicable to constant torque and variable torque load equipment across various industries such as municipal engineering, chemical processing, HVAC, textiles, food, and packaging.
·0.75–1000kW(P type 1.5-1200kW)
·380V-480V
·IP20/IP00/IP21
Additional Information:
| Category | Parameter | Specification |
|---|---|---|
| Power Input | Input Voltage (V) | AC 3PH 380–480V; Rated voltage: 380V |
| Input Current (A) | For details, see the product ratings in the manual. | |
| Input Frequency (Hz) | 50Hz or 60Hz; allowed range: 47–63Hz | |
| Power Output | Output Voltage (V) | 0–Input voltage |
| Output Current (A) | For details, see the product ratings in the manual. | |
| Output Power (kW) | For details, see the product ratings in the manual. | |
| Output Frequency (Hz) | 0–400Hz | |
| Technical Control Performance | Control Mode | Space Voltage Vector Control Mode; No-PG Vector Control Mode |
| Motor Type | Asynchronous Motor (AM) | |
| Speed Ratio | 1:200 (SVC) | |
| Speed Control Accuracy | ±0.2% (SVC) | |
| Speed Fluctuation | ±0.3% (SVC) | |
| Torque Response | Less than 20ms (SVC) | |
| Torque Control Accuracy | 10% (SVC) | |
| Starting Torque | For AMs: 0.25Hz / 150% (SVC) | |
| Overload Capacity | G Type: 150% of rated current for 1 minute and 180% for 10 seconds. P Type: 110% of rated current for 1 minute. Overload is allowed once every 5 minutes. | |
| Running Control Performance | Frequency Setting Method | Settings through digital, analog, pulse frequency, multi-step speed run, simple PLC, PID, and communication. Settings can be combined and channels switched. |
| Automatic Voltage Regulation (AVR) | Output voltage remains constant despite changes in grid voltage. | |
| Fault Protection | Protection against overcurrent, overvoltage, undervoltage, overtemperature, phase loss, and overload. | |
| Speed Tracking Function | Enables smooth startup of a rotating motor. | |
| Peripheral Interface | Terminal Analog Input Resolution | No more than 20mV |
| Terminal Digital Input Resolution | No more than 2ms | |
| Analog Input | Two inputs; AI1: 0–10V / 0–20mA; AI2: -10–+10V | |
| Analog Output | Two outputs; AO1: 0–10V / 0–20mA | |
| Digital Input | Five regular inputs; max. frequency: 1kHz; internal impedance: 3.3kΩ. One high-speed input; max. frequency: 50kHz. | |
| Digital Output | One Y terminal open collector output, sharing the terminal with S4. Function selectable through a jumper. | |
| Relay Output | Two programmable relay outputs. RO1A: NO; RO1B: NC; RO1C: Common. RO2A: NO; RO2B: NC; RO2C: Common. Contact capacity: 3A/250VAC, 1A/30VDC. | |
| Expansion Interfaces | Two expansion interfaces: SLOT1 and SLOT2. Support communication card, I/O card, 24V power supply card, and other expansion cards. | |
| Other Specifications | Mounting Method | Supports wall mounting, floor mounting, and flange mounting. |
| Operating Temperature | -10°C to +50°C. Derating required when ambient temperature exceeds 40°C. | |
| Ingress Protection (IP) Rating | T1–T9 Frames: IP20; T10–T13 Frames: IP00; T14–T15 Frames: IP21 | |
| Pollution Degree | Degree 2 | |
| Cooling Method | 0R7G/1R5P: Natural air cooling. Other models: Forced air cooling. | |
| DC Reactor | T12/T13 and T15 frames: Standard (built-in). | |
| Braking Unit | T1–T5 Frames: Standard (built-in). T6–T8 Frames: Optional (built-in). | |
| EMC Filter | T9–T15 Frames: Standard (built-in C3 filter). With C3 filter, meets IEC 61800-3 C3 requirements. Optional external filters can be used to meet IEC 61800-3 C2 requirements. |