Hope65 Series Smart AC Drive
Hope65 Series Smart AC Drive
Support V/F and Vector control
● Integrated G/P mode
● Built-in DBU
● Removable keypad
● Standard RS485 interface
● Output 0-500Hz
● Automatic torque boost
● Linear/S-curve acceleration and deceleration
Additional Information:
| Home | Descriptions | |
| Input | Power input | AC 1PH, 220V(-15%) ~ 240V(+10%) AC 3PH, 380V(-15%) ~ 440V(+10%) |
| Allowable range | Voltage fluctuating range: -15%~10%; voltage unbalance <3%; frequency: 47Hz~63Hz | |
| Output | Output voltage | Three-phase, 0V~input voltage, tolerance<5% |
| Output frequency range | 0.00 -500.00Hz | |
| Performance | Overload capacity | G mode (heavy duty): 150% of rated current: 60s, 170% of rated current: 12s, 190% of rated current: 1.5s P mode (light duty): 110% of rated current: 60s |
| Frequency resolution | Digital setting: 0.01Hz Analog setting: Max. frequency*0.025% |
|
| Carrier frequency | 0.8 ~ 8 kHz | |
| Input/output
|
Analog input AI | 1 channels AI: 0/4~20mA, 0-10V |
| Analog output AO | 1 channels AO: 0/4~20mA, 0-10V | |
| Digital input | 5 digital inputs, NPN / PNP, 1ph 0.75 and 1.5kW with 4DI. | |
| Digital output | 1 digital output, 1 relay output | |
| PFI / PFO | 1 channel pulse frequency input and output | |
| Communication | Built-in RS485 interface with Modbus RTU | |
| Control functions | Motor control mode | VF control, Sensor-less vector control |
| Run command channel | Operation panel setting, control terminal setting, communication setting | |
| Frequency setting channel | Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI | |
| DC braking | Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current | |
| Jog | Jogging frequency range: 0.10Hz~50.00Hz | |
| AVR | Automatic voltage regulation | |
| Automatic carrier frequency | Automatically regulate carrier frequency according to load characteristic | |
| Dynamic braking unit | All built-in | |
| Environment | Protection | Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat, motor overload, external failure, lost connection of analog input, stall prevention, etc. |
| Altitude | With altitude below 1000m, derate >1000m | |
| Operating | -10~+50℃ / 20~90%RH, without condensation water drop | |
| Storage temperature | -20~+60℃ | |
| Vibration | <5.9m/s2 (0.6g) | |
| Structure | Degree of protection | IP20 |
| Cooling mode | Force-air cooling |