Hope65-SP water pump VFD

Hope65-SP water pump VFD

220v class: 0.75~5.5kW

380v class: 0.75~55kW

Advanced MPPT Algorithm:

Employs an improved algorithm to maximize energy harvest from input power under varying conditions, ensuring optimal power output.

   Comprehensive Voltage Level and Power Range:

Accommodates a wide range of voltage inputs and delivers efficient power conversion across that spectrum.

Additional Information:

Multiple Protection Measures:

Provides robust protection against overvoltage, overcurrent, overheating, and other potential threats, ensuring safe and reliable operation.

User-Friendly Interface:

Features a straightforward and intuitive design that simplifies setup and operation, making it easy for users of all technical backgrounds.

 Removable Keypad:

Offers the convenience of a detachable keypad for programming and system monitoring, promoting flexibility in control and data access.

Specification:

  Items Descriptions
Input Power input Recommend Voc range:  220V: 360~450Vdc;  380V: 550~900Vdc
Recommend Vmp range:  220V: 250~350Vdc.  380V: 450~900VdcMax DC input: 450Vdc(220v class), 380V 900Vdc(380v class)
AC 1PH, 220V(-15%) ~ 240V(+10%)
AC 3PH, 380V(-15%) ~ 440V(+10%)
Allowable range Voltage fluctuating range: -15%~10%; voltage unbalance <3%;

frequency: 47Hz~63Hz

Output Output voltage 220V class: 1PH or 3PH 220V
380V class: 3phase 380V0V~input voltage, tolerance<5%
Output frequency range 0.1 -500.0Hz
Performance Overload capacity G mode (heavy duty): 150% of rated current: 60s, 170% of rated current: 12s, 190% of rated current: 1.5s
P mode (light duty): 120% of rated current: 60s, 150% of rated current: 3s
Frequency resolution Digital setting: 0.01Hz
Analog setting: Max. frequency*0.025%
Carrier frequency 0.8 ~ 8 kHz, can be automatically adjusted according to load characteristics
Input/output Analog input AI 1 channels AI: 0/4~20mA, 0-10V
Analog output AO 1 channels AO: 0/4~20mA, 0-10V
Digital input 5 digital inputs, NPN / PNP, 1ph 0.75 and 1.5kW with 4DI.
Digital output 1 digital output, 1 relay output
PFI / PFO 1 channel pulse frequency input and output
Communication Built-in RS485 interface with Modbus RTU
Control
functions
Motor control mode VF control, Sensor-less vector control
Run command channel Operation panel setting, control terminal setting, communication setting
Frequency setting channel Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI
DC braking Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current
Jog Jogging frequency range: 0.00Hz~Maximum frequency
AVR Automatic voltage regulation
Automatic carrier frequency Automatically regulate carrier frequency according to load characteristic
Environment Protection Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat,
motor overload, external failure, lost connection of analog input, stall prevention, etc.
Altitude With altitude below 1000m, derate >1000m
Operating -10~+50℃ / 20~90%RH, without condensation water drop
Storage temperature -20~+60℃
Vibration <5.9m/s2 (0.6g)
Structure Degree of protection IP20
Cooling mode Force-air cooling