Hope65-SP water pump VFD
Hope65-SP water pump VFD
220v class: 0.75~5.5kW
380v class: 0.75~55kW
Advanced MPPT Algorithm:
Employs an improved algorithm to maximize energy harvest from input power under varying conditions, ensuring optimal power output.
Comprehensive Voltage Level and Power Range:
Accommodates a wide range of voltage inputs and delivers efficient power conversion across that spectrum.
Additional Information:
Multiple Protection Measures:
Provides robust protection against overvoltage, overcurrent, overheating, and other potential threats, ensuring safe and reliable operation.
User-Friendly Interface:
Features a straightforward and intuitive design that simplifies setup and operation, making it easy for users of all technical backgrounds.
Removable Keypad:
Offers the convenience of a detachable keypad for programming and system monitoring, promoting flexibility in control and data access.
Specification:
| Items | Descriptions | |
| Input | Power input | Recommend Voc range: 220V: 360~450Vdc; 380V: 550~900Vdc Recommend Vmp range: 220V: 250~350Vdc. 380V: 450~900VdcMax DC input: 450Vdc(220v class), 380V 900Vdc(380v class) |
| AC 1PH, 220V(-15%) ~ 240V(+10%) AC 3PH, 380V(-15%) ~ 440V(+10%) |
||
| Allowable range | Voltage fluctuating range: -15%~10%; voltage unbalance <3%;
frequency: 47Hz~63Hz |
|
| Output | Output voltage | 220V class: 1PH or 3PH 220V 380V class: 3phase 380V0V~input voltage, tolerance<5% |
| Output frequency range | 0.1 -500.0Hz | |
| Performance | Overload capacity | G mode (heavy duty): 150% of rated current: 60s, 170% of rated current: 12s, 190% of rated current: 1.5s P mode (light duty): 120% of rated current: 60s, 150% of rated current: 3s |
| Frequency resolution | Digital setting: 0.01Hz Analog setting: Max. frequency*0.025% |
|
| Carrier frequency | 0.8 ~ 8 kHz, can be automatically adjusted according to load characteristics | |
| Input/output | Analog input AI | 1 channels AI: 0/4~20mA, 0-10V |
| Analog output AO | 1 channels AO: 0/4~20mA, 0-10V | |
| Digital input | 5 digital inputs, NPN / PNP, 1ph 0.75 and 1.5kW with 4DI. | |
| Digital output | 1 digital output, 1 relay output | |
| PFI / PFO | 1 channel pulse frequency input and output | |
| Communication | Built-in RS485 interface with Modbus RTU | |
| Control functions |
Motor control mode | VF control, Sensor-less vector control |
| Run command channel | Operation panel setting, control terminal setting, communication setting | |
| Frequency setting channel | Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI | |
| DC braking | Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current | |
| Jog | Jogging frequency range: 0.00Hz~Maximum frequency | |
| AVR | Automatic voltage regulation | |
| Automatic carrier frequency | Automatically regulate carrier frequency according to load characteristic | |
| Environment | Protection | Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat, motor overload, external failure, lost connection of analog input, stall prevention, etc. |
| Altitude | With altitude below 1000m, derate >1000m | |
| Operating | -10~+50℃ / 20~90%RH, without condensation water drop | |
| Storage temperature | -20~+60℃ | |
| Vibration | <5.9m/s2 (0.6g) | |
| Structure | Degree of protection | IP20 |
| Cooling mode | Force-air cooling |
- Free First Consultation
Book Your Session With Us Today
Take the first step toward healing. Fill in the form below and our team will reach out within 24 hours to confirm your appointment completely confidential.
Book Your Session With Us Today
- What Happens Next
After You Submit the Form
Here’s exactly what you can expect after booking your session with Azura.
